 +===== Measuring Illuminance =====
 +
 +It is not so simple as it can look, as you need sensor with proper spectral response as well as proper integration hemisphere. 
 +
 +What is the good cheap lux meter that is more or less accurate (it is considered around +-10%)
 +
 +I suggest to get this one - https://www.aliexpress.com/af/lux-meter-lx1010b.html (with large white integration cover).
 +
 +It is far from perfect, but not very bad for many lights. 
 +
 +{{:laboratory:img3010.jpg|}} 
 +
 +{{:laboratory:img3011.jpg|}}
 +
 +{{:laboratory:img3012.jpg|}}
 +
 +{{:laboratory:img3013.jpg|}}
  
 ===== Color quality estimation ===== ===== Color quality estimation =====
Line 30: Line 49:
 will result in a higher score, while larger differences give a lower number. Of all the colors possible, only these eight are measured. Samples used are pastels, not saturated colors. will result in a higher score, while larger differences give a lower number. Of all the colors possible, only these eight are measured. Samples used are pastels, not saturated colors.
  
-CRI is calculated by measuring the difference between the lamp in question and a reference lamp in terms of how they render the eight color samples. If the lamp to be tested has a correlated color temperature (CCT) of less than 5000 Kelvin (K), the reference source is a black body radiator (approximately like an incandescent lamp). For higher CCT sources, the reference is a specifically defined spectrum of daylight. Light sources that+CRI is calculated by measuring the difference between the lamp in question and a reference lamp in terms of how they render the eight color samples. If the lamp to be tested has a correlated color temperature (CCT) of less than 5000 Kelvin (K), the reference source is a black body radiator (approximately like an incandescent lamp).  
 +For higher CCT sources, the reference is a specifically defined spectrum of daylight. Light sources that
 mimic incandescent light or daylight for the eight color samples are, by definition, the ones mimic incandescent light or daylight for the eight color samples are, by definition, the ones
 that will score highest on the CRI. that will score highest on the CRI.
 +
 +{{:laboratory:img2979.jpg}}
  
 Main 8 patches are pastel colors and 8 more patches provide diversity adding more saturated colors and few other useful ones. Main 8 patches are pastel colors and 8 more patches provide diversity adding more saturated colors and few other useful ones.
Line 40: Line 62:
  
 Check good PDF at https://www.konicaminolta.eu/fileadmin/content/eu/Measuring_Instruments/4_Learning_Centre/C_A/What_is_Colour_Rendering_Index/Colour_Rendering_Index_EN.pdf Check good PDF at https://www.konicaminolta.eu/fileadmin/content/eu/Measuring_Instruments/4_Learning_Centre/C_A/What_is_Colour_Rendering_Index/Colour_Rendering_Index_EN.pdf
 +
 +
 +and also this very good one
 +
 +http://ledapplicatie.nl/wp-content/uploads/sites/32/2015/05/6-Konica-Minolta-Sensing-Europe-Color-Rendering-Index.pdf
 +
 +
 +===== CRI Issues =====
 +
 +Some good CRI lights can perform poor on colors, especially red. \\
 +And light that produce pleasing accurate, but saturated colors can have low CRI.  
 +
 +CRI was made mostly for fluorescent measurements, and designed to allow companies to get good results optimizing not for overall color accuracy, but for good looking numbers. 
 +
 +{{:laboratory:img2994.jpg}}
 +
 +{{:laboratory:img2995.jpg}}
 +
 +{{:laboratory:img2996.jpg}}
 +
 +
 +===== Color Quality Scale  =====
 +
 +The CQS is fidelity metric, producing one number like Ra, but the CQS has improvements including the ability to account for the direction of object color shifts. The CQS thus agrees well with visual ratings for color-enhancing sources, while it works as an accurate fidelity metric for non-color-enhancing sources. The CQS score works to
 +represent the overall color quality of products (perceptual color fidelity) for all types of light sources. 
 +
 +{{:laboratory:img2997.jpg}}
 +
 +It uses Root Mean Square to aggregate all 15 patches results, also do not penalize chroma only difference, only color shifts.
 +
 +Usage examples, note that it is very close to CRI for fluos:
 +
 +{{:laboratory:img2998.jpg}}
 +
 +See more details at http://www.seleconlight.com/images/stories/files/Color_Quality_Scale_2010.pdf
 +and http://www1.eere.energy.gov/buildings/publications/pdfs/ssl/cqs_rationale_06-10.pdf
 +
 +
 +===== TM-30 Color Fidelity  =====
 +
 +99 reference colors, graphical representation of results, lots of useful stuff.
 +
 +Check more detail at http://www.cormusa.org/uploads/CORM_2016_Ohno_presentation_TM-30__rev_.pdf
 +
 +{{:laboratory:img3001.jpg}}
 +
 +{{:laboratory:img3002.jpg}}
 +
 +{{:laboratory:img3003.jpg}}
 +
 +===== TM-30 Samples  =====
 +
 +{{:laboratory:s267.jpg}}
 +
 +{{:laboratory:s268.jpg}}
 +
 +{{:laboratory:s269.jpg}}
 +
 +{{:laboratory:s270.jpg}}
 +
 +{{:laboratory:s271.jpg}}
 +
 +
 +===== TM-30 Rf versus CRI Ra  =====
 +
 +{{:laboratory:s272.jpg}}
 +
 +
 +===== Color Indexes Future  =====
 +
 +Check https://www.energystar.gov/sites/default/files/asset/document/Energy%20Star%20webinar%20Presentation%20-%20Ohno%202.pdf
  
 ===== Color Rendering and efficiency conflict ===== ===== Color Rendering and efficiency conflict =====
Line 63: Line 156:
  
 Free at https://www.konicaminolta.eu/fileadmin/content/eu/Measuring_Instruments/4_Learning_Centre/L_D/The_language_of_Light/language_of_light.pdf Free at https://www.konicaminolta.eu/fileadmin/content/eu/Measuring_Instruments/4_Learning_Centre/L_D/The_language_of_Light/language_of_light.pdf
 +
 +**Illimination fundamentals**
 +
 +{{:laboratory:img2981.jpg}}
 +
 +
 +Free at   
 +https://optics.synopsys.com/lighttools/pdfs/illuminationfund.pdf
  
  